TEST REPORT BY PSB CORPORATION

 

Ref: 54S042515/2/SSL

Date: 7 Jun 2004

 

Tested for JVL Engineering Pte Ltd

 

Test Method

 

BS 5412 : 1996 Specification for low-resistance single taps and combination tap assemblies (nominal size 1/2 and 3/4) suitable for operation at PN 10 max. and a minimum flow pressure of 0.01 MPa (0.1 bar).

 

Method of flow rate was conducted in accordance with Clause 10 of BS 5412 : 1996 except that the running pressure was at 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 and 550 kPa instead of 10 kPa.

 

Location Of Test

 

No.1 Science Park Drive

 

 

Extracted Data

ECO-SAVE Water Saving Device Performance

“Renee” Sink Tap with 6L-1900

 

 

 

 

 

 

    Sample Reference

ECO-SAVE water saving device + "Renee" sink tap

  Characteristics

 

6L-1900

"Renee" sink tap

% saved

 

   0 kPa

0

0

0

 

   50 kPa

1.1

13.5

92

 

   100 kPa

1.6

19

92

 

   150 kPa

1.9

23.4

92

  Flow rate test at various running

   200 kPa

2.3

27.1

92

  pressure (l/min.)

   250 kPa

2.6

31

92

 

   300 kPa

2.8

34.6

92

 

   350 kPa

3.1

-

-

 

   400 kPa

3.2

-

-

 

   450 kPa

3.4

-

-

 

   500 kPa

3.5

-

-

 

   550 kPa

3.6

-

-