TEST REPORT BY PSB CORPORATION
Ref:
54S042515/2/SSL
Date:
Tested for
JVL Engineering Pte Ltd
Test Method
BS 5412 : 1996 Specification for low-resistance single taps and
combination tap assemblies (nominal size 1/2 and 3/4) suitable for operation at
PN 10 max. and a minimum flow pressure of 0.01 MPa (0.1 bar).
Method of flow rate was conducted in
accordance with Clause 10 of BS 5412 : 1996 except that the running pressure
was at 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 and 550 kPa instead of 10 kPa.
Location Of
Test
No.1
|
Extracted Data |
||||
|
ECO-SAVE
Water Saving Device Performance “Renee” Sink Tap with 6L-1900 |
||||
|
|
|
|
|
|
|
|
Sample Reference |
ECO-SAVE
water saving device + "Renee" sink tap |
||
|
Characteristics |
|
6L-1900 |
"Renee"
sink tap |
%
saved |
|
|
0 kPa |
0 |
0 |
0 |
|
|
50 kPa |
1.1 |
13.5 |
92 |
|
|
100 kPa |
1.6 |
19 |
92 |
|
|
150 kPa |
1.9 |
23.4 |
92 |
|
Flow rate
test at various running |
200 kPa |
2.3 |
27.1 |
92 |
|
pressure (l/min.) |
250 kPa |
2.6 |
31 |
92 |
|
|
300 kPa |
2.8 |
34.6 |
92 |
|
|
350 kPa |
3.1 |
- |
- |
|
|
400 kPa |
3.2 |
- |
- |
|
|
450 kPa |
3.4 |
- |
- |
|
|
500 kPa |
3.5 |
- |
- |
|
|
550 kPa |
3.6 |
- |
- |